High Power Laser and Particle Beams, Volume. 32, Issue 2, 025021(2020)

Hardware compensation of B-dot low frequency characteristics in cavity

Bing Wei... Junjun Kang, Jie Wang, Jiabin Fu, Zhen Fu and Shuping Feng |Show fewer author(s)
Author Affiliations
  • Key Laboratory of Pulsed Power, Institute of Fluid Physics, CAEP, P. O. Box 919-108, Mianyang 621999, China
  • show less

    The output signal of B-dot probe in the cavity increases at low frequency. The first-order correction method of “a characteristic flux-penetration time” is analyzed. According to the analysis, the method of compensation with integrator is proposed. Frequency response experiments were carried out for B-dot installed in the electrodes of coaxial and radial lines. The results show that when the RC time constant of the integrator is equal to the characteristic flux-penetration time, the measurements of B-dot coincide with the standard current signal. Therefore, for the B-dot probe in the cavity, this is the principle of selecting the RC constant of the integrator. The compensated test results are obtained directly by hardware, thus it is more convenient to operate than the software correction method.

    Tools

    Get Citation

    Copy Citation Text

    Bing Wei, Junjun Kang, Jie Wang, Jiabin Fu, Zhen Fu, Shuping Feng. Hardware compensation of B-dot low frequency characteristics in cavity[J]. High Power Laser and Particle Beams, 2020, 32(2): 025021

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Aug. 12, 2019

    Accepted: --

    Published Online: Mar. 18, 2020

    The Author Email:

    DOI:10.11884/HPLPB202032.190309