Journal of Atmospheric and Environmental Optics, Volume. 10, Issue 2, 158(2015)

Monitoring of VOCs Emissions of Yanjia Industrial Park in Chongqing Based on SOF-FTIR Technology

Chongzhi ZHAI1、*, Ruiling LIU1, Liping XU1, Ling JIN2, Jiayan YU1, Li LI1, and Min LIU1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    Volatile organic compounds (VOCs), which participated in photochemical reactions, were main precursor of photochemical pollution, and also the critical pollutants that currently affected China’s urban air quality. The pollution situation of VOCs was complex and had many unknown factors, due to the lack of convenient and fast monitoring measurement. The technology of solar occultation flux based on FTIR(SOF-FTIR)was used to rapidly scan pollution areas for real-time monitoring, and it was found that vertical column density peak values of most VOCs was ranged from 10 ppm·m to 60 ppm·m, and local pollution was easily formed.

    Tools

    Get Citation

    Copy Citation Text

    ZHAI Chongzhi, LIU Ruiling, XU Liping, JIN Ling, YU Jiayan, LI Li, LIU Min. Monitoring of VOCs Emissions of Yanjia Industrial Park in Chongqing Based on SOF-FTIR Technology[J]. Journal of Atmospheric and Environmental Optics, 2015, 10(2): 158

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Received: Nov. 12, 2014

    Accepted: --

    Published Online: Apr. 14, 2015

    The Author Email: Chongzhi ZHAI (czz66818@sina.com.cn)

    DOI:10.3969/j.issn.1673-6141.2015.02.008