Infrared and Laser Engineering, Volume. 47, Issue 10, 1030002(2018)
Wavelength selection and detection capability simulation of the mid-infrared DIAL for NO2 detecion
Differential absorption lidar(DIAL) is an effective way to measure the concentration of nitrogen dioxide in extensive air with high precision. Based on the tunable solid-state laser absorption technique, the principle and systematic structure of differential absorption lidar were introduced. The absorption spectra of nitrogen dioxide in the range from 3.410 μm to 3.435 μm were measured with a step of 0.01 nm. The experimental results show that the correlation coefficient between the measured and the simulated absorption spectrum reaches to 92.01% at the standard condition (i.e., 1.0 atm, 25 ℃). Based on the analysis of measured absorption spectrum,the laser wavelength pair which includes the on-line 3.424 μm and the off-line 3.414 μm is determined. In addition, the signal pre-processing and denoising methods were studied. The simulation results show that the concentration errors of nitrogen dioxide can be less than ±0.1 mg/m3 within 1 km by combining the signal pre-processing and the multiple autocorrelation.
Get Citation
Copy Citation Text
Xu Ling, Bu Lingbing, Cai Haoze, Sa Rina, Yang Bin, Zhou Jun. Wavelength selection and detection capability simulation of the mid-infrared DIAL for NO2 detecion[J]. Infrared and Laser Engineering, 2018, 47(10): 1030002
Category: 激光雷达技术
Received: May. 7, 2018
Accepted: Jun. 12, 2018
Published Online: Nov. 25, 2018
The Author Email: