Infrared Technology, Volume. 43, Issue 6, 607(2021)

Effect of Orifice Size on Flow Stability of Shape Memory Alloy Self-Regulated Cryocoolers

Xiangxiang GUO* and Penglei HAN
Author Affiliations
  • [in Chinese]
  • show less

    The flow stability of shape memory alloy (SMA) self-regulated cryocoolers with different orifice sizes is analyzed via theoretical calculation and experimental study. The theoretical calculation demonstrates that the smaller the orifice diameter, the more stable is the flow rate when the cryocoolers are influenced by the same disturbance factors. The change in flow rate increases linearly with the increase in orifice diameter. In the experimental investigation, two types of SMA self-regulated cryocoolers, equipped with 0.15 mm and 0.25 mm orifices, respectively, were developed. Fatigue and vibration tests were introduced as disturbance factors. The flow rates of cryocoolers were evaluated at 29 and 22 MPa. The results show that the cryocoolers with a 0.15 mm orifice have smaller flow rate variance than those with a 0.25 mm orifice. Both the theoretical and experimental results verified that narrowing the diameter of the orifice is conducive to the flow stability of SMA self-regulated cryocoolers.

    Tools

    Get Citation

    Copy Citation Text

    GUO Xiangxiang, HAN Penglei. Effect of Orifice Size on Flow Stability of Shape Memory Alloy Self-Regulated Cryocoolers[J]. Infrared Technology, 2021, 43(6): 607

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Sep. 3, 2020

    Accepted: --

    Published Online: Aug. 26, 2021

    The Author Email: Xiangxiang GUO (gxxgxx1234@126.com)

    DOI:

    Topics