BLASTING, Volume. 38, Issue 1, 147(2021)

Experimental Study on Anti-shock Performance of Explosion-resistant Door of Converter Transformer Valve Hall

YANG Li-bo1、*, ZHAO Xin-yu1, DONG Yi-fu1, FU Wan-zhang1, and REN Jia-fan2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    As an important safety protection facility of converter transformer valve hall,the explosion-resistant door should meets high quality requirements.Therefore,it is of great practical value to study the anti-shock performance of the explosion-resistant door of the valve hall.The anti-shnock performance of the explosion-resistant door filled with foam aluminum and nothing filled was studied and verified experimentally under the shock wave condition of 300 kPa and 1000 kPa,respectively.The anti-shock performance of the two different doors was evaluated through the amount of deformation,whose maximum values turned out to be 2 mm and 3 mm.The experimental results show that the explosion-resistant door with aluminum foam filling has better anti-shorck performance under higher loadings.

    Tools

    Get Citation

    Copy Citation Text

    YANG Li-bo, ZHAO Xin-yu, DONG Yi-fu, FU Wan-zhang, REN Jia-fan. Experimental Study on Anti-shock Performance of Explosion-resistant Door of Converter Transformer Valve Hall[J]. BLASTING, 2021, 38(1): 147

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: Oct. 30, 2020

    Accepted: --

    Published Online: Jan. 25, 2024

    The Author Email: Li-bo YANG (286915326@qq.com)

    DOI:10.3963/j.issn.1001-487x.2021.01.023