Acta Optica Sinica, Volume. 32, Issue 3, 312006(2012)

Dichromatic Interferogram of Lubricant Film Measurement

Zhou Guangmei1、*, Guo Feng1, and Li Hongsheng1,2
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    The multi-beam interference and the CCD camera spectral response, a colorimetric model is established for the interference measurement of lubricating-film thickness. A computation program is built for rendering the interferograms generated by a dichromatic light source in the lubricating-film measurement. For a static ball-glass disc contact, the results of theoretical simulation and experiment of the red-green dichromatic interferograms are agreed. Analyses show that the dichromatic interferogram is mainly influenced by the full width of half maximum (FWHM) of the green-red filter, the thickness of the beam splitter, the spacer thickness and the lubricants. A small FWHM, 4~10 nm of the beam splitter thickness and low spacer thuickness can lead to high contrast of interference fringes.

    Tools

    Get Citation

    Copy Citation Text

    Zhou Guangmei, Guo Feng, Li Hongsheng. Dichromatic Interferogram of Lubricant Film Measurement[J]. Acta Optica Sinica, 2012, 32(3): 312006

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Instrumentation, Measurement and Metrology

    Received: Aug. 3, 2011

    Accepted: --

    Published Online: Feb. 20, 2012

    The Author Email: Guangmei Zhou (zgmno.1@163.com)

    DOI:10.3788/aos201232.0312006