Optical Communication Technology, Volume. 47, Issue 5, 40(2021)

Fabrication and performance analysis of fiber Bragg grating pH sensor embedded in anchor cable

ZHANG Qunying1... YAN Lei2, JIANG Xue1, KANG Wenbo1 and ZHU Wanxu1,* |Show fewer author(s)
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    In view of the problems that the existing fiber grating pH sensor can not be used for the detection of pH in the anchor cable due to its narrow response range, low sensitivity and limited application, this paper puts forward a method that fiber Bragg grating(FBG) pH sensor is embedded in the anchor cable to monitor the pH inside the cable. The working principle of FBG pH sensor is analyzed, and the FBG pH sensor is embedded in the steel strand for corresponding experimental research. The test results show that when the pH is 4-11, there is an optimum coating thickness in the FBG pH sensor embedded in the anchor cable, which makes the sensitivity of the sensor to the maximum value of pH response, and the FBG pH sensor embedded in the steel strand does not change the temperature characteristics of FBG.

    Tools

    Get Citation

    Copy Citation Text

    ZHANG Qunying, YAN Lei, JIANG Xue, KANG Wenbo, ZHU Wanxu. Fabrication and performance analysis of fiber Bragg grating pH sensor embedded in anchor cable[J]. Optical Communication Technology, 2021, 47(5): 40

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category:

    Received: May. 28, 2020

    Accepted: --

    Published Online: Sep. 2, 2021

    The Author Email: Wanxu ZHU (zhuwanxu@vip.163.com)

    DOI:10.13921/j.cnki.issn1002-5561.2021.05.009

    Topics