Laser & Optoelectronics Progress, Volume. 52, Issue 6, 62202(2015)

Study on Alignment Technology of Scanning Pentaprism System for Testing Large Flat Mirrors

Qi Erhui1,2、*, Luo Xiao2,3, Liu Quan1,2, Zheng Ligong2,3, and Zhang Xuejun2,3
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • 3[in Chinese]
  • show less

    The scanning pentaprism system (PPS) is an effective method for guiding large flat optical processing, due to its advantages such as simple structure, high testing efficiency and precise measurement of low order aberrations. This paper established PPS′s mathematical model according to vectorial ray tracing theory, the analytical relationship between PPS′s performance and its components′ angular motion is obtained by least square fitting, which is useful for analyzing PPS′s sensitivity to components′ alignment errors. Afterward a fine alignment procedure is proposed. Experimental results show that PPS′s measurement error caused by alignment is better than 40 nrad after fine alignment. The result shows that PPS is practical for large flat testing.

    Tools

    Get Citation

    Copy Citation Text

    Qi Erhui, Luo Xiao, Liu Quan, Zheng Ligong, Zhang Xuejun. Study on Alignment Technology of Scanning Pentaprism System for Testing Large Flat Mirrors[J]. Laser & Optoelectronics Progress, 2015, 52(6): 62202

    Download Citation

    EndNote(RIS)BibTexPlain Text
    Save article for my favorites
    Paper Information

    Category: Optical Design and Fabrication

    Received: Dec. 27, 2014

    Accepted: --

    Published Online: Apr. 20, 2015

    The Author Email: Erhui Qi (qierhui@mail.ustc.edu.cn)