Laser & Optoelectronics Progress, Volume. 50, Issue 7, 71501(2013)

Calibration Method of Low-Resolution Sensor Based on Bilinear Interpolation Strategy

Cheng Xiangzheng1、*, Zeng Zhaoyang2, Chen Hang1, and Huang Chao1
Author Affiliations
  • 1[in Chinese]
  • 2[in Chinese]
  • show less

    For non-scanning laser three-dimensional (3D) imaging sensors, the imaging resolution is low and the calibration accuracy is not high. In order to solve this problem, a low-resolution sensor calibration method based on bilinear interpolation is proposed.Firstly, a resampling strategy based on the bilinear interpolation algorithm is used to improve the image resolution. Then calibration algorithm based on OpenCV is adopted. Finally the calibration results are compared with those obtained by the traditional calibration method. Experimental results show that the calibration error is reduced by nearly 1/2. The proposed calibration method based on bilinear interpolation algorithm can improve the calibration accuracy of low-resolution sensor.