Photonic Sensors
Co-Editors-in-Chief
Yunjiang RAO
Hongcai ZHAO, Yanbin LIU, Tayyab FAROOQ, and Hui FANG

Photoacoustic Doppler flow measurement based on continuous wave laser excitation owns the merit of clearly presenting the Doppler power spectra. Extending this technique to dual wavelengths can gain the spectral information of the flow sample extra to the flow speed information. An experimental system with two laser diodes respectively operated at 405 nm and 660 nm wavelengths is built and the flow measurement with black and red dyed polystyrene beads is performed. The measured Doppler power spectra can vividly reflect the flow speed, the flow direction, as well as the bead color. Since it is straightforward to further apply the same principle to multiple wavelengths, we can expect this type of spectroscopic photoacoustic Doppler flow measurement will be developed in the near future which will be very useful for studying the metabolism of the slowly moving red blood cell inside microvessels.

Jan. 01, 1900
  • Vol. 12 Issue 1 1 (2022)
  • Kankan SWARGIARY, Romuald JOLIVOT, and Waleed Soliman MOHAMME

    A polymer based horizontal single step waveguide for the sensing of alcohol is developed and analyzed. The waveguide is fabricated by 3-dimensional (3D) printing digital light processing (DLP) technology using monocure 3D rapid ultraviolet (UV) clear resin with a refractive index of n = 1.50. The fabricated waveguide is a one-piece tower shaped ridge structure. It is designed to achieve the maximum light confinement at the core by reducing the effective refractive index around the cladding region. With the surface roughness generated from the 3D printing DLP technology, various waveguides with different gap sizes are printed. Comparison is done for the different gap waveguides to achieve the minimum feature gap size utilizing the light re-coupling principle and polymer swelling effect. This effect occurs due to the polymer-alcohol interaction that results in the diffusion of alcohol molecules inside the core of the waveguide, thus changing the waveguide from the leaky type (without alcohol) to the guided type (with alcohol). Using this principle, the analysis of alcohol concentration performing as a larger increase in the transmitted light intensity can be measured. In this work, the sensitivity of the system is also compared and analyzed for different waveguide gap sizes with different concentrations of isopropanol alcohol (IPA). A waveguide gap size of 300 μm gives the highest increase in the transmitted optical power of 65% when tested with 10 μL (500 ppm) concentration of IPA. Compared with all other gaps, it also displays faster response time (t = 5 seconds) for the optical power to change right after depositing IPA in the chamber. The measured limit of detection (LOD) achieved for 300 μm is 0.366 μL. In addition, the fabricated waveguide gap of 300 μm successfully demonstrates the sensing limit of IPA concentration below 400 ppm which is considered as an exposure limit by “National Institute for Occupational Safety and Health”. All the mechanical mount and the alignments are done by 3D printing fused deposition method (FDM).

    Jan. 01, 1900
  • Vol. 12 Issue 1 10 (2022)
  • Yifan DUAN, Yang ZHANG, Fang WANG, Yuting SUN, Ming CHEN, Zhenguo JING, Qiao WANG, Mengdi LU, and Wei PENG

    In this paper, we propose and demonstrate a high-performance mercury ion sensor with sub-nM detection limit, high selectivity, and strong practicability based on the small molecule of the 4-mercaptopyridine (4-MPY) modified tilted fiber Bragg grating surface plasmon resonance (TFBG-SPR) sensing platform. The TFBG-SPR sensor has a rich mode field distribution and a narrow bandwidth, which can detect the microscopic physical and chemical reactions on the sensor surface with high sensitivity without being disturbed by the external temperature. For the environmental compatibility and highly efficient capture of the toxic mercury ion, 4-MPY is modified on the sensor surface forming a stable (4-MPY)-Hg-(4-MPY) structure due to the specific combination between the nitrogen of the pyridine moiety and the Hg2+ via multidentate N-bonding. Moreover, gold nanoparticles (AuNPs) are connected to the sensor surface through the (4-MPY)-Hg-(4-MPY) structure, which could play an important role for signal amplification. Under the optimized conditions, the limit of detection of the sensor for mercury ions detection in the solution is as low as 1.643×10–10 M (0.1643 nM), and the detection range is 1×10–9 M – 1×10–5 M. At the same time, the mercury ion spiked detection with tap water shows that the sensor has the good selectivity and reliability in actual water samples. We develop a valuable sensing technology for on-time environmental Hg2+ detection and in-vivo point of care testing in clinic applications.

    Jan. 01, 1900
  • Vol. 12 Issue 1 23 (2022)
  • Emily CIRULNICK, Haopeng ZHANG, and David KLOTZKIN

    The use of optical sensors for oxygen measurement is becoming more important because of their capability for low-cost and direct measurement, but as yet, little has been reported about their long-term performance. Phosphorescent sensors based on platinum octaethylporphyrin (PtOEP) embedded in polymer matrices tend to degrade with time. To reduce the rate of degradation, sensor films were fabricated and then coated with a layer of polydimethylsiloxane (PDMS) and tested in a six-month study. The PDMS-coated sensors showed an average degradation rate of ~0.073 %/day, compared to ~0.18 %/day for uncoated sensors. Titania beads were also incorporated into the films to increase light scattering and improve the response; these beads compensated to some degree for the absorption due to the PDMS films. The films with titania beads improved the response significantly (about 40%) compared to the films without titania beads. Incorporation of titania beads also moderately improved the aging characteristics.

    Jan. 01, 1900
  • Vol. 12 Issue 1 68 (2022)
  • Kediliya WUMAIER, Gulgina MAMTMIN, Qingrong MA, Asiya MAIMAITI, Patima NIZAMIDIN, and Abliz YIMIT

    The detection of hydrogen sulfide (H2S) is essential because of its toxicity and abundance in the environment. Hence, there is an urgent requisite to develop a highly sensitive and economical H2S detection system. Herein, a zinc phthalocyanine (ZnPc) thin film-based K+-exchanged optical waveguide (OWG) gas sensor was developed for H2S detection by using spin coating. The sensor showed excellent H2S sensing performance at room temperature with a wide linear range (0.1 ppm – 500 ppm), reproducibility, stability, and a low detection limit of 0.1 ppm. The developed sensor showed a significant prospect in the development of cost-effective and highly sensitive H2S gas sensors.

    Jan. 01, 1900
  • Vol. 12 Issue 1 74 (2022)
  • Haibin CHEN, Tianchong XIE, Jiashuang FENG, Xiongxing ZHANG, Wei WANG, Yanping LI, and Zilong GUO

    A fiber-optic temperature sensor based on fiber tip polystyrene microsphere is proposed. The sensor structure can be formed simply by placing and fixing a polystyrene microsphere on the center of an optical fiber tip. Since polystyrene has a much larger thermal expansivity, the structure can be used for high-sensitive temperature measurement. By the illuminating of the sensor with a broadband light source and through the optical Fabry-Perot interference between the front and back surfaces of the polystyrene microsphere, the optical phase difference (OPD) or wavelength shift can be used for the extraction of temperature. Temperature measurement experiment shows that, using a fiber probe polystyrene microsphere temperature sensor with a spherical diameter of about 91.7 μm, a high OPD-temperature sensitivity of about –0.617 96 nm/℃ and a good linearity of 0.991 6 were achieved in a temperature range of 20 ℃–70 ℃.

    Jan. 01, 1900
  • Vol. 12 Issue 1 84 (2022)
  • Zhuoyue LI, Zengling RAN, Xianguo QING, Zhengxi HE, Yaqin XIAO, Tingting YANG, Xiu HE, Jialiang ZHU, Peng HE, and Sijie XU

    The sensing characteristics of irradiated fiber Bragg gratings (FBGs) and Fabry-Perot interferometers (FPIs) were investigated under a 2 MGy dose of gamma radiation. The study found that the pressure sensitivity of FP sensors after irradiation was stable, while the temperature sensitivity of FBG sensors was unstable, and both wavelengths displayed a shift. These findings offer the possibility for the application of FP pressure sensors in the gamma radiation environments, and FBG sensors require further research to be suitable for application in the nuclear radiation environments.

    Jan. 01, 1900
  • Vol. 12 Issue 1 91 (2022)
  • Farhad LARKI, Yaser ABDI, Parviz KAMELI, and Hadi SALAMATI

    Graphene as a truly 2-dimensional (2D) system is a promising candidate material for various optoelectronic applications. Implementing graphene as the main building material in ultra-broadband photodetectors has been the center of extensive research due to its unique absorption spectrum which covers most of the electro-magnetic spectra. However, one of the main challenges facing the wide application of pure graphene photodetectors has been the small optical absorption of monolayer graphene. Although novel designs were proposed to overcome this drawback, they often need complicated fabrication processes in order to integrate with the graphene photodetector. In this regard, fabrication of purely graphene photodetectors is a promising approach towards the manufacturing of simple, inexpensive, and high photosensitive devices. The fabrication of full graphene photodetectors (FGPDs) is mainly based on obtaining an optimal technique for the growth of high quality graphene, modification of electronic and optical properties of the graphene, appropriate techniques for transfer of graphene from the grown substrate to the desire position, and a proper design for photodetection. Therefore, the available states of the art techniques for each step of device fabrication, along with their pros and cons, are reviewed and the possible approaches for optimization of FGPDs have been proposed.

    Jan. 01, 1900
  • Vol. 12 Issue 1 31 (2022)
  • Please enter the answer below before you can view the full text.
    5-2=
    Submit